Surging in centrifugal compressors pdf

It is defined as the lower limit of stable operation of the compressor. Centrifugal air compressor basics key concepts centrifugal compressors are most effective when running at full capacity. Centrifugal and axial compressors will surge when forward flow through the compressor can no longer be maintained, due to an increase in pressure across the compressor, and a. Compressor the compressor assembly is made up of a prime mover and a centrifugal compressor. Surging and choking in centrifugal compressor in fluid power. Axial compressors figure 2 handle much higher flowrates than centrifugal compressors, but. Surging takes place when compressor is operated off the design point and it affects the whole machine and this is aerodynamically and mechanically undesirable. The compressor behavior during surge differs at different diffuser vane angles. Choke and surge occur at the extreme ends of the performance curve and should be avoided. Models describing this interaction were developed in 8 and 12 for axial compressors, and in 10 and 15 a preliminary version of this paper for centrifugal compressors. Elliott compressors and turbines installed in the 1940s and 1950s are still in operation today, either as originally supplied or upgraded to handle new process conditions or more stringent environmental standards. Positive displacement compressors confine volumes of air or gas in an enclosed space, which is reduced to accomplish compression. How inlet conditions impact centrifugal air compressors.

The turbo compressor surge is an unstable operating mode of compression system that occurs at mass flows below the socalled surge line. Centrifugal compressor surge and speed control article pdf available in ieee transactions on control systems technology 75. Daikin chillers use liquid refrigerant cooled hermetic electric motors. Sep 25, 2017 ask a chemical or mechanical engineer, what does a compressor surge do, and he would shudder merely thinking of the consequences. Apr 14, 2017 in this article, we will see the centrifugal compressor surgebasics, mechanism and also we will see how the surge takes place in centrifugal compressor with an example. The surge is starting with the instant flow reverses, shown in the above figure. Since compressors are variable speed machines, it is of interest to investigate the in.

In contrast, dynamic compressors convert energy from the prime mover into kinetic energy in the gas being compressed, which is then converted to pressure. In air compressors, surge control can be accomplished by opening a discharge end bypass valve and venting air to the atmosphere. Even small quantities of liquids shall have detrimental effect on centrifugal compressor rotors. Hvac made easy selection tips for chiller compressors. Modelling of surge phenomena in a centrifugal compressor taylor. However, if the machine is allowed to surge repeatedly over a long. In centrifugal compressor, what is difference between surging and choking. Surge control design for centrifugal compressor systems three levels of dynamic surge analysis compressor reliability is directly affected by the interaction between the surge controller, piping system, valves, recycle lines and coolers. Jul 23, 2017 surge problem occurs in the centrifugal turbo compressor, when compressor flow is reduced by throttling suction inlet valve. The instability is characterized by large limit cycle oscillations in compressor flow and pressure rise. Centrifugal compressor surge, modeling and identification for.

Centrifugal compressors are typically used in large chillers. Surging and choking in centrifugal compressor in fluid. Pdf flow phenomena leading to surge in a centrifugal. Actually, the working principle of a centrifugal compressor is increasing the kinetic energy of the fluid with a rotating impeller. Operation near surge as well as preventing compressors from surging, has drawn significant amounts of attention moore et al, 2009. Surge is a condition that occurs on compressors when the amount of gas they are trying to compress is insufficient for the speed of the compressor and the turbine blades lose their forward thrust, causing a reverse movement in the shaft. Understanding centrifugal compressor capacity controls. Surging is well explained in thread 403110655 of this forum. During surge back flow at the compressor happens and can causes severe. The centrifugal compressor is a dynamic device similar to a centrifugal water pump.

Surge dynamics and unsteady flow phenomena in centrifugal. Centrifugal compressors an overview sciencedirect topics. Answer zahid akhtar centrifugal compressor surge is seen as a very dangerous and detrimental phenomenon in compressed air systems, dangerous because it causes the compressor to vibrate and detrimental because it causes damage to the compressor parts. Pdf previous work on stabilization of compressor surge is extended to include control of the angular velocity of the compressor.

Section a consists of an introduction to surge and a discussion of centrifugal compressor design and process factors that affect operating stability. The operating range of compressors is bounded by flow instabilities at low massflow rates. By using two different test rig layouts, instabilities occurring in the compressor, beyond the peak of the characteristic curve, are identified and investigated. The phenomena of stall and surge in axial centrifugal compressors is investigated through highresponse measurements of both the pressure field and the flowfield throughout the surge cycle.

Compressor loadsharing control and surge detection techniques. Protecting a centrifugal compressor from surge pipeline. Surge is a characteristic behaviour of a centrifugal compressor that can occur when inlet flow is reduced such that the head developed by the compressor is insufficient to. Performance characteristics of centrifugal compressors. We have been on the cutting edge of technological advancement throughout our history, consistently. A centrifugal gas compressor having a shrouded rotatable impeller 14 in an impeller chamber 40, and provided with capacity control vanes 30 and a diffuser passage 18 throttle plate 38, is provided with surge control means including a thermistor 50 which senses a temperature rise beyond a predetermined value in the impeller chamber and exterior of the gas flow path through the impeller, and. Centrifugal compressor surge, modeling and identification. What is surging in reciprocating compressor answers. Royal belgian institute of marine engineers surge detection. Case study of surge avoidance design for centrifugal. What is surging and choking in centrifugal compressor. Pdf surge detection system for centrifugal compressor.

When the centrifugal compressor operates at low mass flow rates close to the unstable operating condition called surge, flow instabilities may develop and severe flow reversal may occur in the. Mechanism of stall and surge in a centrifugal compressor with. As surge can occur during acceleration of the compressor speed, it is of major concern to develop controllers that simultaneously can control both surge and compressor speed. Publishers pdf, also known as version of record includes final page, issue. Surge detection and surge control systems for centrifugal compressors part 2. In this paper, the mechanism of stall and surge in a centrifugal compressor with a variable vaned diffuser is experimentally investigated, where the diffuser blade setting angle can be adjusted. Compressor loadsharing control and surge detection. Piping systems around the compressor must be designed to minimize the volume in the compressor. Avoiding compressor surge when operating multiple centrifugal compressors case study. Aug 21, 2018 in this video i have explained surging and choking in centrifugal compressor with pressure ratio verses mass flow rate diagram. In this video, i explained surging and choking of centrifugal compressor. Manual purpose to be used for selection, application into the system, power and cooling water estimation. To expand the stable operating range of compressors, understanding the mechanism of flow instability at low flow rates is necessary.

Previous work on stabilization of compressor surge is extended to include control of the angular velocity of the compressor. A loworder centrifugal compressor model is presented, where the states. The fluid is then slowed down in a volume called the plenum, where the kinetic energy is converted into potential energy in form of a. A wide compressor functionality range is essential to supply boost pressure at all engine operating conditions. The compressor assembly is made up of a prime mover and a centrifugal compressor. We analyzed four cases of existing centrifugal compressor systems, three co2 compression systems and one off. The term describes violent air flow oscillating in the axial direction of a compressor, which indicates the axial component of fluid velocity varies periodically and may even become negative. Centrifugal compressor surge and speed control control. How to read a centrifugal compressor performance curve.

Troubleshooting compressor problems salemmbrothers. Esd of all 3 units at the same time however, when beta simulated the scenario of a unit 8 trip or fast stop while all three compressors were in operation, an important design risk with the system design was identified. If you look through the performance curves of the compressor you would find a a line sloping down from right to the left. Minimum flow point in a centrifugal or axial compressor. Us4363596a method and apparatus for surge detection and. An accurately designed surge control system that includes multiple compressors with the associated piping systems is a vital element of a facilitys design and ongoing operational integrity. Axial and centrifugal compressors application guide. I am confused as to how does stalling and surging occur in compressors. In this paper, the mechanism of stall and surge in a centrifugal compressor with a variable vaned diffuser is experimentally investigated, where the.

The course of the surge is decreasing mass flow rate and increases a rotational speed of the impell. Fundamentals include dynamic centrifugal compressor map, operating envelope, surge cycle. Many of the devices, which incorporate surge detection function, use either the location of the operating point. Surge in centrifugal and axial compressors often manifests itself as oscillations of flow and pressure, as well as related compressor parameters, such as rotating speed. Surging is a momentary back flow through the compressor from the discharge to the suction. Compressor capacity should be stated at plant conditions, which are actual cubic feet per minute acfm. Dynamic compressors include centrifugal and axial flow types. Part 3integrally geared centrifugal compressors, specifies integrally geared centrifugal compressors in conjunction with api 617, part 1. Surging may occur in a compressor when, at a certain pump pressure, the gas velocity through the compressor becomes too low, or when, at a certain gas. Robust adaptive control of surge instability in constant. Any process manufacturer that has centrifugal compressors knows about a condition known as surge. In centrifugal compressor, what is difference between surging.

Mechanism of stall and surge in a centrifugal compressor. Surge is one of the two dynamic instabilities that occur in centrifugal compressors and can pose severe safety issues to the compression system. When the diffuser vane angle is adjusted, both the unstable form and the core factor. Surging figure shows mass flow rate vs pressure ratio of compressor. Centrifugal compressor surge choke chemical engineering site. This can occur when the mass flow of gas to the compressor falls below a critical level with a high pressure difference. Most compressors are designed to withstand occasional surging. In this curve, the differential pressure is on the vertical axis and inlet flow rate is on the horizontal axis. Now we will see how the surge starts in a compressor. Many facilities employ two or more centrifugal compressors, operated in either series or parallel configurations. The developed surge model could better control the considered system. This manual does not for designing centrifugal compressor and those parts. Compressor surge only occur in centrifugal compressors.

Surge is a complete breakdown of steady flow through the compressor. Section 3 description of surge 31 surge versus stall surge is a dynamic instability that occurs in dynamic compressors. In centrifugal compressors these occurrences can damage the interstageeye labyrinth seals, impellers, couplings, and the compressor driver. A centrifugal compressor is a machine that imparts energy to the gas flowing through it.

Mechanism of stall and surge in a centrifugal compressor with a. Compressor surge is a form of aerodynamic instability in axial compressors or centrifugal compressors. Centrifugal technology is based on dynamic compression. Surging is the complete breakdown of steady flow in the compressor which occurs at low flow rate. Reciprocating and scr oll compressors are typically used in small chillers. Apparently surging is the lower limit of operation for the compressor but i dont. In centrifugal compressor, what is difference between. Surge control design for centrifugal compressor systems. Surging and choking of centrifugal compressor youtube. Understand your process, as well as the advantages and disadvantages of each centrifugal compressor configuration, in order to choose the optimal centrifugal compressor for your application. This paper tries to investigate the active surge control methods in centrifugal compressors. As mentioned earlier, this particular clinic discusses centrifugal water chillers. To this end, mooregreitzer compressor model is used, which considers a close couple. Detailed time resolved measurements of centrifugal compressor surge has been obtained on an automotive turbocharger.

Centrifugal compressor surgebasics, mechanism mechanical. In screw compressor, oil is injected into the rotor chamber for sealing and lubrication purposes and. Lets analyze what will occur when a valve placed in the delivery line of a compressor running at constant speed is slowly opened the variation in pressure ratio is shown above centrifugal compressor performance curve 3. As for the noise elimination a roaring noise due to surging when condenser water temperature drops,it is due to the reduction in the lift that needs to be created by the compressor under these conditions. Vadodara institute of engineering name chaturvedi anupam 140803119501 surging and choking 2. It raises the pressure and temperature of the refrigerant by converting kinetic energy into pressure. Surge control considerations in centrifugal compressors. The key difference between such compressors and pumps is that the compressor working fluid is a gas compressible and the pump working fluid is liquid incompressible. Surge protection system design is crucial in avoiding any damage in abnormal circumstances such as emergency shutdown esd, startup, coastdown operation, and normal shutdown. It can damage the rotor bearings, rotor seals, compressor driver and affect the whole cycle operation. Replacing and elaborating those polynomials, we get the expressions of. Pdf surge is a global flow instability occurring in centrifugal compressors at low massflow rate operation.

The test facility is set up in order to obtain i the compressor performance maps at rotational speeds up to 25,000 rpm and ii the compressor transient behavior during surge. Ported shroud casing treatment is widely used to delay the onset of surge and thereby enhancing the aerodynamic stability of a centrifugal compressor by recirculating the low momentum fluid in the. Us3292845a method for preventing surging of compressors. What is surging choking and stalling in compressor mecholic. Centrifugal compressor surge, modeling and identification for control.

Avoiding compressor surge when operating multiple centrifugal. To understand compressor surge, a solid understanding of how a compressor actually works is needed. Centrifugal compressors are commonly employed in automotive turbochargers to increase the specific efficiency of internal combustion engines. Nov 14, 2016 centrifugal compressor performance characteristic curve is the curve between polytropic head and inlet volume flow. In this video i have explained surging and choking in centrifugal compressor with pressure ratio verses mass flow rate diagram. The compressor develops maximum differential pressure head is called surge. Another effect of the change in air or gas density is the available turndown of the compressor. The surge usually starts in one stage of a multistage compressor and can occur very rapidly. Sorokes dresserrand selecting a centrifugal compressor inlet pressure p1 temperature t1. Axial and centrifugal compressors draw their names from the primary direction in which the flow moves within the compressor.

Compressor surge only occurs in dynamic compressors axial and centrifugal due to their nature. The surge limit defines the flow at which, for a given speed, the operation of the compressor becomes unstable. These machines do not have gears integral with their casing but can have external gears. In this paper, a surge control law for variable speed centrifugal compressors is presented and. What is stalling, surging and choking in compressor. The instability is characterized by large limit cycle oscillations in compressor.

With an increase in compressor inlet flow rate, the head developed by the centrifugal compressor start decreases. Compression systems with centrifugal compressors are widely used in gas involving processes. When a centrifugal compressor surges, there is an actual reversal of gas flow through the compressor impeller. The inlet temperature of the air has an impact on the density of the air at the intake of the compressor and will influence the kinetic energy transferred by the blades to the air. At flow rates below the surge limit the characteristic curve actually droops toward zero flow after having reached its maximum point at the surge limit. Understanding centrifugal compressor surge and control. Experimental investigation of stall and surge in a. Generation mechanisms of rotating stall and surge in. Centrifugal compressors are also similar to centrifugal pumps of the style shown in the adjacent figures. Axial compressors are also part of this class of turbo machines. Axial and centrifugal compressors application guide ge oil gas. Helicalrotary or screw compressors are typically used in mediumsized chillers. What is surging choking and stalling in compressor mecholic no comments. If flow is reduced below this point, cyclic variation and even reversal of gas flow and discharge pressure.

In this article, we will see the centrifugal compressor surge basics, mechanism and also we will see how the surge takes place in centrifugal compressor with an example. Control systems for centrifugal compressors part 2. The centrifugal compressors surge simulation 47 based on those values, the coefficients a1 of the two polynomials which approximate the compressor performance at n 0. Pdf the dynamics of stall and surge behavior in axial. Surge is defined as the operating point at which centrifugal compressor peak head capability and minimum flow limits are reached. Plant engineering centrifugal air compressor basics. A centrifugal compressor is usually fitted with antisurge controls which detect any approach to the surge conditions and open the bypass from the delivery to the suction of the machine, thus increasing the flow through the machine and moving it away from the surge conditions. Operation of centrifugal compressors in choke conditions. Centrifugal compressor surge is seen as a very dangerous and detrimental phenomenon in compressed air systems, dangerous because it causes the compressor to vibrate and detrimental because it causes damage to the compressor parts. Explain the methods of capacity control of centrifugal compressor. The potentially damaging effects of surging compressors are widely acknowledged. Cagi and our centrifugal customers all share a common interest and goal to maximize the compressor system efficiency and optimize the system energy usage. In a characteristic curve the terms like compressor surge line, anti surge line, choke or stone wall point are the important phenomenon to be understood. Compressor surge is typically controlled by detecting when the compressor is nearing the surge line on the compressor characteristic curve and modifying the compressor operation to avoid entering into a surge cycle.

275 611 999 229 843 1166 1475 824 1425 915 371 249 1487 963 93 1050 1522 873 1384 1106 150 610 666 275 600 34 264 874 1165 963 836 1203 95 1204